Characteristics and Performance
Reaction to fire
Euroclass A1 in accordance with UNE-EN 13501-1-2019
Durability
Class B
Properties
Veneto Batten Bending Tests
- Maximum permitted permanent deflection = 0.20 mm
- Average permanent deflection = 0.13 mm
- Flexural rigidity EI (Class 2) = 7.45×108 N·mm2
- Permissible bending moment (Class 2) = 1.99×104 N·mm
U-20 Perimeter Profile Bending Tests
- Maximum permitted permanent deflection = 0.20 mm
- Average permanent deflection = 0.05 mm
- Permissible bending moment (Class 2) = 5.07×103 N·mm
Hanging Component Functional Test
- Forces applied:
- Fsup = F adm = 873 N
- Finf = 0.4·Fadm = 349 N
Regulations


Colours and Dimensions
Dimensions
This model has various finishes available: staves separated by a groove, with a bolted moulding in different colours, or with a closed groove. This allows the product to offer an increased number of usage possibilities. The colours of our staves combine in an original way with indoor and outdoor spaces. The option of accessing the plenum space facilitates maintenance and repair work on lighting, plumbing and air conditioning systems.
Finishes


Please consult us for the prices of other colours
*Option of wood finishes
Installation and Cleaning
- Staves must be stored in dry, well-ventilated places away from heat sources and out of direct sunlight and rain.
- THU Profile ceilings are installed during the last phase of construction, meaning once all enclosures and facilities have already been put in position.
- Ceiling models that are protected by a plastic film should have this film removed as soon as possible to properly ventilate the false ceiling once installed.
- The area where the ceiling is to be installed must be clean and free of obstacles that hinder the installation procedure; furthermore, all other construction work (plaster, dry construction, etc.) and painting must be completed in the spaces where the false ceiling is to be installed to avoid stains and dust build-ups on its sheets.
- The area where the ceiling is to be installed must be clean and free from obstacles that hinder the installation process.
- The ceiling should be installed in ambient conditions of temperature (15-25ºC) and humidity (35-75%).